Home       About us        Products        Certificate       Feed back       Contact us
     
 
 
Electrical Items >> Switching Power Supply >> Q-60 Quadri Output Power Supply  

Q-60 Quadri Output Switching Power Supply

type

Q-60

  DC VOLTAGE

5V

12V

-5V

-12V

  VOLTAGE TOLERANCE

±2%

±6%

±5%

±5%

  RATED CURRENT

5.5A

2A

0.5A

0.5A

  CURRENT RANGE

0.5-8A

0.1-3A

0-1A

0-1A

  RIPPLE&NOISE(MAX.)

100mVp-p

120mVp-p

100mVp-p

120mVp-p

  LINE REGULATION

±0.5%

±1%

±0.5%

±0.5%

  LOAD REGULATION

±0.5%

±4%

±1%

±1%

  RATED POWER

60W

  EFFICIENCY(Typ.)

70%

  VOLTAGE ADJ.RANGE

CH1:+10,-5%

  VOLTAGE RANGE

85264VAC 47-63Hz;120-370VDC

  AC CURRENT

1.3A/115V 0.8A/230V

  INRUSH CURRENT(MAX.)

cold inrushed current 18A/115V 60A/230V

  LEAKAGE CURRENT

<1mA/240VAC

  OVERLOAD PROTECTION

105%-150% typeoutput cutout :auto recovery

  OVERVOLTAGE PROTECTION

CH1:5.75-6.75

  OVERTEMPERATURE PROTECTION

......................

  TEMP.COEFFICIENT

±0.03%/(050)

  SETUP.RISE,HOLD TIME

1.6s,20ms,12ms/115VAC 800ms,20ms,60ms/230VAC

  WITHSTAND VOLTAGE

I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC

  ISOLATED RESISTOR

I/P-O/P,I/P-FG,O/P-FG:500VDC/100MΩ

  WORKING TEMP.HUMIDITY

-10+60,20%90RH

  STORAGE TEMP.HUMIDITY

-20+85,10%95%RH

  DIMENSION

159×97×38mm

  WEIGHT

0.55Kgs

  SAFETY STANDARDS

UL1950

  EMC

CISPR22(55022),IEC801--2,3,4,IEC555-2


Note

1.All parameters NOT specially mentioned are measured at 230VAC input ,rated load and 25 of ambient temperature. 2.Tolerance:includes set up tolerance,line regulation and load regulation
3.Ripple&noise are measured at 20MHZ of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf&47uf parallel capacitor.
4.line regulation:min&max voltage of the rated load.
5.load regulation:load from 0 to 100%.
    

hits:1344    addtime:2010-10-23 [back

 
 
 
 
 

TEL:0086-577-27838284  Fax:0086-577-56847980  E-MAIL: sales@eraelectric.com