INDEX TYPE |
T-60-A |
T-60-B |
T-60-C |
DC VOLTAGE |
5V |
12V |
-5V |
5V |
12V |
-12V |
5V |
15V |
-15V |
VOLTAGE ADJ.RANGE |
+10%-5% |
|
|
+10%-5% |
|
|
+10%-5% |
|
|
VOLTAGE TOLERANCE |
±2% |
±6% |
±6% |
±2% |
±6% |
±6% |
±2% |
±6% |
±6% |
RATED CURRENT |
5A |
2.5A |
0.5A |
5A |
2.5A |
0.5A |
5A |
2A |
0.5A |
CURRENT RANGE |
0.5-7A |
0.2-3.5A |
0-1A |
0.5-7A |
0.2-3.5A |
0-1A |
0.5-7A |
0.2-3A |
0-1A |
RATED POWER |
57.5W |
61W |
62.5W |
EFFICIENCY(Typ.) |
72% |
72% |
72% |
RIPPLE&NOISE(MAX.) |
100mvp-p |
100mvp-p |
100mvp-p |
100mvp-p |
100mvp-p |
100mvp-p |
100mvp-p |
100mvp-p |
100mvp-p |
LINE REGULATION |
±0.5% |
±1% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±1% |
±0.5% |
LOAD REGULATION |
±1% |
±4% |
±4% |
±1% |
±4% |
±4% |
±1% |
±4% |
±4% |
VOLTAGE RANGE |
85-264VAC 47-63Hz 120-370VDC |
AC CURRENT |
2A/115VAC 1A/230VAC |
INRUSH CURRENT(MAX.) |
cold inrushed current 30A/115V 60A/230VAC |
LEAKAGE CURRENT |
<1mA/240V |
OVERLOAD PROTECTION |
105-150% type :output cutout ,auto recovery |
OVERVOLTAGE PROTECTION |
5V:5.75-6.75V |
OVERTEMPERATURE PROTECTION |
-- |
TEMP.COEFFICIENT |
±0.03%/℃(0-50℃) |
SETUP.RISE,HOLD TIME |
800ms 50ms 10ms /115VAC , 300ms 50ms 80ms /230VAC |
WITHSTAND VOLTAG |
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC |
ISOLATED RESISTOR |
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC |
STORAGE TEMP.HUMIDITY |
0-50℃@100%,-10℃@80%,60℃@60%,20%-90%RH |
WEIGHT |
0.5Kg |
SAFETY STANDARDS |
UL1012 TUVEN60950 DC(1950) |
EMC |
CLSPT22(EN55022)CLASSB,IEC801-2,3,4.IEC555-2. |
Note: 1.All parameters NOT specially mentioned are measured at 230VAC input ,rated load and 25 of ambient temperature. 2.Tolerance:includes set up tolerance,line regulation and load regulation 3.Ripple&noise are measured at 20MHZ of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf&47uf parallel capacitor. 4.line regulation:min&max voltage of the rated load. 5.load regulation:load from 0 to 100%. |