¡¡ Home       About us        Products        Certificate       Feed back       Contact us
¡¡ ¡¡ ¡¡
¡¡
¡¡
Electrical Items >> Cam Switch >> KT10 Cam Controller ¡¡

KT10 Series AC cam controller
  1. use 
        The KT10 series AC cam controller (hereafter refers to as
    controller), mainly uses in AC 50HZ voltage to start, the
    velocity modulation to 380 volts electric motors, and using of the
    commutation, also is suitable for the similar request other electric
    drive systems.

  2. sort¡¢type and meanings

    2£®1  The KT10 series controller according to fixed gives off heat the electric current to divide 25A and the 60A two kinds
    2£®2  Model and meaning
     

  3. technical datasort

    3£®1The controller basic parameter see Table 1

    TYPE

    Position number

    Rated current £¨A£©

    Controller rated power (Kw)   380 V

    Operating force(N)

    Mechanical life£¨Million times £©

    The number of open & close times in one hour no more than

    left

    right

    KT10-60J/1

    5

    5

    60

    30

    ¡Û50

    1£®5

     

    KT10-60J/2

    5

    5

    60

    ¢Ù

    ¡Û50

    1£®5

     

    KT10-60J/3

    1

    1

    60

    16

    ¡Û50

    1£®5

     

    KT10-60J/5

    5

    5

    60

    2¡Á11

    ¡Û50

    1£®5

     

    KT10-25J/1

    5

    5

    25

    11

    ¡Û50

    1£®5

     

    KT10-25J/2

    5

    5

    25

    ¢Ù

    ¡Û50

    1£®5

     

    KT10-25J/3

    1

    1

    25

    5

    ¡Û50

    1£®5

     

    KT10-25J/5

    5

    5

    25

    2¡Á5

    ¡Û50

    1£®5

     

    KT10-60J/13F

    5

    5

    60

    30

    ¡Û50

    1£®5

    600¢Û

    KT10-60J/14F

    6

    6

    60

    2¡Á11

    ¡Û50

    1£®5

     

    KT10-60J/15F

    6

    6

    60

    ¢Ù

    ¡Û50

    1£®5

     

    KT10-60J/24

    4

    4

    60

    16

    ¡Û50

    1£®5

     

    KT10-25J/13F

    5

    5

    25

    11

    ¡Û50

    1£®5

     

    KT10-25J/14F

    6

    6

    25

    2¡Á5

    ¡Û50

    1£®5

     

    KT10-25J/15F

    6

    6

    25

    ¢Ù

     

     

     

    KT10-25J/24

    4

    4

    25

    5

    ¡Û50

    1£®5

     

    3£®2Controller stator contact putting through breaks with the minute
    3£®2£®1The control winds thread the type electrical machinery the controller
    to see Table 2

    Controller contact type

    The parameter of Put through & break

    Test time

    Test interval£¨S£©

    Electrifie duration/time£¨ms£©

    I/Ie

    U/Ue

    COS§¶¡À0.05

    Reversible transformation(time)

    onoff(time)

    switch on(time)

    Stator contact

    4

    1.1

    0.65

    5

    20

    100

    5~10

    60~200

    Note (1) I:Test current, (2) Ie:Rated heating current, (3) U: Testing voltage, (4) Ue: Rated working voltage.
    3£®2£®2The control mouse cage type electrical machinery controller see Table

    control

    The parameter of Put through & break

    Test time

    Oscilation frequencyf¡À10%(KHX)

    Crosses vibration coefficient r0.05

    Experimental gap (S)

    Each time electrifies the time (ms)

    TYPE

    I/Ie

    U/Ue

    COS§¶¡À0.05

    Reversible transformation(hypo)

    Puts through the number of times(hypo)

    Puts through the minute to break

     

     

    KTJ10-25J/3

    12

    10

    0.55

    25

    100

    2000¡Á10.2¡ÁUe-0.8

    1.1

    5~10

    6~200

    KTJ10-60J/3

    0.35

    Note (1) I:Test current 
    (2) Ie:The control mouse cage type electrical machinery working voltage is 380 volt KT10-25J/3 controller fixed operating current is 10A.The control mouse cage type electrical machinery working voltage is 380 volt time KT10-60J/3 controller fixed operating current is 25A.
    (3)U£ºTesting voltage¡££¨4£©Ue£ºFixed working voltage.
    3£®3 The controller assists the contact putting through to break the ability with the minute to see Table 4.

  4. Electric current category

    The contact fixed gives off heat the electric current

    Passes breaks the condition

    Experimental number of times(hypo)

    pitch time(S)

    Power On Hours(S)

    intercourse£¨A£©

    voltage£¨V£©

    COS§¶¡À0.05

    intercourse

    5

    8.8

    1.1¡Á380

    0.2

    50

    5~10

    0.06~0.2

    3£®4 Controller stator electric circuit contact electricity life.

    3£®4£®1The control winds thread the type electrical machinery the controller to see Table 5¡£

    TYPE

    on-off time

    operating frequency£¨hypo/ hour£©

    Power On Hours£¨S£©

    Life number of times (ten thousand)

    electricity£¨A£©

    voltage£¨V£©

    COS§¶¡À0.05

    KT10

    2£®5le

    380

    0£®65

    600

    0£®06~0.2

    5

    3.4.2The control mouse cage type electrical machinery controller sees table

    PRODUCT TYPE

    Power On Hours

    Oscilation frequencyf¡À10%(KHZ)

    Crosses the vibration coefficient f¡À0.05

    perating frequency(hypo/hour)

    Power On Hours(S)

    Life number of times    (ten thousand)

    electricity£¨A£©

    voltage£¨V£©

    COS§¶¡À0.05

    KTJ10-25J/3

    6le

    380

    0.55

    2000¡Á10.2¡ÁUe-0.8

    1.1

    600

    0.06-0.2

    5

    KTJ10-60J/3

    0.35

    Note: (1) le: The control mouse cage type electrical machinery working voltage is 380 volt time KT10-25J/3 controller fixed operating current is 11A.
    The control mouse cage type electrical machinery working voltage is 380 volt time KT10-60J/3 controller fixed operating current is 25A.
    3£®5The auxiliary contact electricity life parameter see Table 7      

    PRODUCT TYPE

    The rating gives off heat the electric current (A)

    on condition

    The minute breaks the condition

    Life number of times

    electricity£¨A£©

    voltage£¨V£©

    COS§¶¡À0.05

    electricity£¨A£©

    voltage£¨V£©

    COS§¶¡À0.05

    KT10

    5

    8

    380

    0£®2

    0£®8

    0£®25

    0£®25

    20Íò

    3£®6The controller control power, may refer to the limit to pass breaks the ability, the electricity life parameter designation¡£

  5. overall dimension and installation dimension
    4£®1 KT10-25J/1The controller contour and installs the size to see Figure 1¡£

    Attempts the 1KT10-25J/1 controller outline drawing

    TYPE

    KT10-25J/1

    KT10-25J/2

    KT10-25J/3

    KT10-25J/5

    A

    KT10-25J/13F

    KT10-25J/15F

    KT10-25J/24

    KT10-25J/14F

    346¡À4.85

    346¡À4.85

    346¡À4.85

    426¡À4.85

    C

    206¡À3.6

    222¡À3.6

    206¡À3.6

    286¡À4.05

    4.2KT10-60J/The controller contour and installs the size to see chart 2.

    Chart 2 KT10-60J/Controller outline drawing

    TYPE

    KT10-60J/1

    KT10-60J/2

    KT10-60J/3

    KT10-60J/5

    B

    KT10-60J/13F

    KT10-60J/15F

    KT10-60J/24

    KT10-60J/14F

    422¡À4.85

    422¡À4.85

    422¡À4.85

    522¡À5.5

    C

    252¡À4.05

    272¡À4.05

    252¡À4.05

    352¡À4.45

  6. Chart 2 KT10-60J/Controller outline drawing

      The controller structure see Figure 3 and chart 4 Is loaded with the cam shaft in the outer covering (1), the
    prop (2) and fixes on the prop the contact system (3). The contact system makes the rotation type single break point, (6) on has the roller in the moving contact release lever (5); Has the inside lining pottery clay ferroguinous extinguishing of arc cover on the stator return route contact system; Has the ferroguinous extinguishing of arc on the partial rotors electric circuit contact system to cover (4). The controller localization is by locates the notch wheel (8), locates the release lever (7), the retaining spring (9) realizes. The controller makes the protected type, has the steel plate outer covering, about the base for cast irons the workpiece. When the cam shaft rotates, the contact system separates according to stipulation procedure Guan Hehe.
     

  7. Along with product supply engineering factor
    a¡¢Packing list£»b¡¢Product certificate£»c¡¢Product instruction booklet


     



     
  8. use and servicing
    7£®1The controller must reliably install on the wall or the bracket.
    7£®2When wiring must according to the controller electrical schematic
    diagram wiring, all wires draw out by the base lower extremity two
    wiring holes¡£
    7£®3In front of the circular telegram, must inspect the controller, the
    electric motor, the resistor, the protection screen, the limit switch
    and the brake magnet connection is whether correct, must inspect
    earths whether reliably, then carries on the idling revolution. If the
    controller changes to time the first grade of position, the electric
    motor has not started to rotate, after then should stop supplying
    power verifies the reason, only then continues to start. After the
    electric motor from starts to revolve speed control to, the controller
    only then changes to the next position, when transits from a position
    to another position, the surge current should not surpass the relay
    installation working current. Like wants to stop the electric motor,
    should return the controller to the reference (nulling operation).
    7£®4The controller should the periodic inspection, each week not be
    supposed to be short in, and must observe the following request.
    7£®4£®1Should maintain in the friction spot has a thin layer the lubricant
    (to be possible to use industry vaseline oil).
    7£®4£®2The contact active face should not have the big melt spot, burns the
    melt the spot to be possible to use the superfine file careful repair,
    but does not allow the use sandpaper to repair and maintain.
    7£®4£®3The contact active face should not have the big melt spot, burns the
    melt the spot to be possible to use the superfine file careful repair,
    but does not allow the use sandpaper to repair and maintain.
    7£®4£®4Eliminates in the controller the dust and the soil, may use the
    compressed air or do the cloth to wipe.
    7£®4£®5Has damaged the components should promptly replace.

hits£º2822    addtime£º2009-09-26 £Ûback£Ý

¡¡
¡¡
¡¡
¡¡
¡¡

TEL:0086-577-27838284  Fax:0086-577-56847980  E-MAIL: sales@eraelectric.com