| General (HBES/P series variable frequency three-phase(power type)emergency power supply) |
a. Application: supply variable frequency three -phase emergency power supply for fire facility only having s ingle power supply or motor of primary load , to solve the problem of motor power supply and reduce the impulse to power device during starting. Example: water pump motor, fan motor or other devices motors. b. Specification range: 2.2KW-800KW c. Detail specification: 2.2, 3.7, 5.5, 7.5, 11, 15, 18.5, 22, 30, 37, 45, 55, 75, 93, 110, 132, 160, 187, 200, 220, 250, 280, 315, 400, 500KW, etc. d. Installation: floor type ( standard power distribution box) Standby time: 120min, it also can be set according todesign requirement. |
| Main technical parameters (HBES/P series variable frequency three-phase(power type)emergency power supply) |
| Model |
HBES/P-2.2~500KW |
| Input |
Voltage |
380 ¡À 20% |
| Phase no. |
Three-phase four-wire +PE |
| Frequency |
50Hz ¡À 5% |
| Output |
Capacity |
2.2KW~500KW |
| Voltage |
0~380V (adjustable) three-phase four-wire +PE |
| Waveform |
PWM wave |
| Frequency |
0~50Hz (Start through inversion and run normally, frequency is adjustable) |
| Overload capacity |
60s for120%; 0.5s for 150% |
| Battery |
Maintenance-free sealing battery |
| Switching time |
Standard type: 120min (may be set according to design requirement) |
| Protection |
Short circuit protection, over current protection, phase failure protection |
| Display |
LED |
| Efficiency |
Emergency power supply: above 95%; |
| Running environment |
Temp.: -24 ~40 Relative humidity:0~90% Altitude: 2,000m below |
| Applicable load |
Only for motor loads |
| Noise |
Commercial power: no noise; emergency power supply: less than 60dB. |
| Size/weight |
See the table of size/weight |
The way of opening the door and incoming wire |
Single open of front door, double-open of back door, inlet and outlet wire from bottom (for standard type) | |
| Battery equipping and size/weight table (HBES/P series variable frequency three-phase(power type)emergency power supply) |
| No. |
Model |
Output power (KW) |
Size of battery cabinet (mm)D¡ÁW¡ÁH |
Battery cabinet(Pcs.) |
Weight(kg) |
| 1 |
HBES/P-2.2KW |
2.2
|
----- |
Battery in the main frame |
160(Including battery) |
| 2 |
HBES/P-3.7KW |
3.7
|
----- |
Battery in the main frame |
340(Including battery) |
| 3 |
HBES/P-5.5KW |
5.5
|
----- |
Battery in the main frame |
700(Including battery) |
| 4 |
HBES/P-7.5KW |
7.5
|
----- |
Battery in the main frame |
800(Including battery) |
| 5 |
HBES/P-11KW |
11
|
----- |
Battery in the main frame |
950(Including battery) |
| 6 |
HBES/P-15KW |
15
|
800¡Á600¡Á2200 |
1Pcs. |
1280(Including battery) |
| 7 |
HBES/P-18.5KW |
18.5
|
800¡Á600¡Á2200 |
1Pcs. |
1300(Including battery) |
| 8 |
HBES/P-22KW |
22
|
800¡Á600¡Á2200 |
1Pcs. |
1740(Including battery) |
| 9 |
HBES/P-30KW |
30
|
800¡Á600¡Á2200 |
1Pcs. |
1800(Including battery ) |
| 10 |
HBES/P-37KW |
37
|
800¡Á600¡Á2200 |
2Pcs. |
2420(Including battery ) |
| 11 |
HBES/P-45KW |
45
|
800¡Á600¡Á2200 |
2Pcs. |
3350(Including battery ) |
| 12 |
HBES/P-55KW |
55
|
800¡Á600¡Á2200 |
2Pcs. |
3360(Including battery ) |
| 13 |
HBES/P-75KW |
75
|
800¡Á600¡Á2200 |
3Pcs. |
4960(Including battery ) |
| 14 |
HBES/P-93KW |
93
|
800¡Á600¡Á2200 |
4Pcs. |
6570(Including battery ) |
| 15 |
HBES/P-110KW |
110 |
800¡Á600¡Á2200 |
4Pcs. |
6580(Including battery ) | |
|