SP-1000 Switching Power Supply

  • Low price and high reliability
  • 105¡æ output capacitor
  • AC input power suitable for the world
  • High efficiency and low operation temperature
  • Soft-start current can reduce the AC input impact effectiely
  • With short-circuit and owwerload protection
  • 100% full-load burning test
  • Installed with EMI filter,minimum wave
  • Model

    Performance
    SP-1000-12 SP-1000-15 SP-1000-24 SP-1000-48
    DC output voltage 12V 15V 24V 48V
    Output voltage error(Note:2) ¡À1% ¡À1% ¡À1% ¡À1%
    Rated output current 80A 53A 33A 17A
    Output current rage 0-80A 0-53A 0-33A 0-17A
    Wave and noise(Note:3) 120mVp-p 150mVp-p 150mVp-p 240mVp-p
    Inlet stability(Note:4) ¡À0.5% ¡À0.5% ¡À0.5% ¡À0.5%
    Load stability(Note:5) ¡À1% ¡À1% ¡À1% ¡À1%
    DC output power 1000W 1000W 1000W 1000W
    Efficiency 82% 84% 86% 88%
    Adjustable range for DC voltage 10-13.2V 12-15V 20-26.5V 41-56V
    Range for input votage 186~230VAC,47~63HZ
    Input current 7A/115V 3.5A/230V
    Impact current 18A/115V 36A/230V
    Leakage current <3.5mA/240VAC
    Overload proctection 105%¡«135% TYPE Foldback Cut off output RESET:Self-Reset
    Over-voltage protection
    13.8~16.2V
    15.5~18.2V
    27.6~32.4V
    57.6~67.2V
     
     
    High-temperature protection RTH1 OR RTH2>=50¡æ FAN ON,<=45¡æ FAN OFF,>=70¡æ Cut off output
    Temperature factor ¡À0.03%¡æ(0~50¡æ)
    Start,rise and lock time 200ms,100ms,30ms
    Vibration resistance 10~500Hz,2G 10min./1cycle,time60,minutes for each shaft
    Resistance to pressure

    Input and output internal:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC

    Insolationg resistance Input and output internal,input and enclosure,Output and enclosure:500VAC/100M Ohms
    Operating temperature and humidity -10¡æ~+50¡æ,20%~90%RH
    Store temperature and humidity -20¡æ~+85¡æ,10%~95%%RH
    Overall dimension 280*180*125mm
    Weight 6.0Kgs
    Safety standard DESIGN REFER TO UL1950 TUV EN60950
    EMC standard DESIGN REFER IEC1000-42,3,4,5,6,8,11 IEC100-3-2
    Note:1.The testing condition for the paramenter above is :230VAC input,rated load, 25¡æ 70% RH.Humidity
    ¡¡¡¡ 2.Error.include the setting error,line stability and load stability.(Note:5)
    ¡¡¡¡ 3.Wave test:adopting A12" double wire for 20MHz, and 1.2UF&47UF capacitor short-circuit for interrupting.
    ¡¡¡¡ 4.Inlet voltage stability test:when is over load, the lowest voltage of inlet is up to the highest voltage.
    ¡¡¡¡ 5.Load stability test:The load is from 0% to 100%
    ¡¡¡¡ 6.C3,4 must be knocked down.