SP-400 Switching Power Supply |
Low price and high reliability
105¡æ output capacitor
AC input power suitable for the world
High efficiency and low operation temperature
Soft-start current can reduce the AC input impact effectiely
With short-circuit and owwerload protection
100% full-load burning test
Installed with EMI filter,minimum wave |
 | |
Model
Performance |
SP-400-5 |
SP-400-9 |
SP-400-12 |
SP-400-15 |
SP-400-24 |
SP-400-48 |
DC output voltage |
5V |
9V |
12V |
15V |
24V |
48V |
Output voltage error(Note:2) |
¡À2% |
¡À2% |
¡À1% |
¡À1% |
¡À1% |
¡À1% |
Rated output current |
55A |
43A |
33A |
26A |
17A |
8.3A |
Output current rage |
0-55A |
0-43A |
0-33A |
0-26A |
0-17A |
0-8.3A |
Wave and noise(Note:3) |
240mVp-p |
240mVp-p |
240mVp-p |
240mVp-p |
200mVp-p |
300mVp-p |
Inlet stability(Note:4) |
¡À0.5% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
Load stability(Note:5) |
¡À1% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
DC output power |
400 |
400 |
400 |
400 |
400 |
400W |
Efficiency |
72% |
76% |
82% |
84% |
86% |
88% |
Adjustable range for DC voltage |
10-13.2V |
12-15V |
13.5-18V |
20-26.4V |
24-30V |
41-56V |
Range for input votage |
90-132VAC,180~264VAC BY SWITCH 47~63Hz; |
Input current |
15A/115V ,30A/230V |
Impact current |
18A/115V 36A/230V |
Leakage current |
<3.5mA/240VAC |
Overload proctection |
115%¡«135% TYPE Foldback Cut off output RESET:Self-Reset |
Over-voltage protection |
13.8~16.2V |
15.5~18.2V |
18~21V |
27.6~32.4V |
31~36.5V |
57.6~67.2V |
High-temperature protection |
RTH1 OR RTH2>=50¡æ FAN ON,<=45¡æ FAN OFF,>=70¡æ Cut off output |
Temperature factor |
¡À0.03%¡æ(0~50¡æ) |
Start,rise and lock time |
200ms,100ms,30ms |
Vibration resistance |
10~500Hz,2G 10min./1cycle,time60,minutes for each shaft |
Resistance to pressure |
Input and output internal:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC |
Insolationg resistance |
Input and output internal,input and enclosure,Output and enclosure:500VAC/100M Ohms |
Operating temperature and humidity |
-10¡æ~+50¡æ,20%~90%RH |
Store temperature and humidity |
-20¡æ~+85¡æ,10%~95%%RH |
Overall dimension |
215*115*50mm |
Weight |
2.3Kgs |
Safety standard |
DESIGN REFER TO UL1950 TUV EN60950 |
EMC standard |
DESIGN REFER IEC1000-42,3,4,5,6,8,11 IEC100-3-2 |
Note:1.The testing condition for the paramenter above is :230VAC input,rated load, 25¡æ 70% RH.Humidity ¡¡¡¡ 2.Error.include the setting error,line stability and load stability.(Note:5) ¡¡¡¡ 3.Wave test:adopting A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting. ¡¡¡¡ 4.Inlet voltage stability test:when is over load, the lowest voltage of inlet is up to the highest voltage. ¡¡¡¡ 5.Load stability test:The load is from 0% to 100% ¡¡¡¡ 6.C3,4 must be knocked down. | | |
|