¡¡ Home       About us        Products        Certificate       Feed back       Contact us
¡¡ ¡¡ ¡¡
¡¡
¡¡
Electrical Items >> Switching Power Supply >> PS-280 Switching Power Supply ¡¡

PS-280 Switching Power Supply

  • Low price and high reliability
  • 105¡æ output capacitor
  • AC input power suitable for the world
  • High efficiency and low operation temperature
  • Soft-start current can reduce the AC input impact effectiely
  • With short-circuit and owwerload protection
  • 100% full-load burning test
  • Installed with EMI filter,minimum wave
  • Model

    Performance
    PS-280-13.5 PS-280-27
    DC output voltage 13.5V 27V
    Output voltage error(Note:2) ¡À1% ¡À1%
    Rated output current 20A 10A
    Output current rage 0-20A 0-10A
    Wave and noise(Note:3) 150mVp-p 150mVp-p
    Inlet stability(Note:4) ¡À0.5% ¡À0.5%
    Load stability(Note:5) ¡À0.5% ¡À0.5%
    DC output power 270W 270W
    Efficiency 80% 82%
    Adjustable range for DC voltage 12-15V 24-30V
    Range for input votage 90~132VAC/180~264VAC BY SWITCH 47~63Hz;254~370VDC
    Input current 5.5A/115V 3A/230V
    Impact current 35A
    Leakage current <0.75mA/240VAC
    Overload proctection 105%¡«135% TYPE:FOLDBACK CUT OFF OUTPUT RESET:SELF-RESET
    Over-voltage protection
    115%-135%
    High-temperature protection RTH3>=60¡æ FAN ON,<=50¡æ FAN OFF,>=90¡æ CUT OFF OUTPUT
    Temperature factor ¡À0.03%¡æ(0~50¡æ)
    Start,rise and lock time 200ms,50ms,10ms
    Vibration resistance 10~500Hz,2G 10min./1cycle,time60,minutes for each shaft
    Resistance to pressure

    Input and output internal:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC

    Insolationg resistance Input and output internal,input and enclosure,Output and enclosure:500VAC/100M Ohms
    Operating temperature and humidity -10¡æ~+50¡æ,20%~90%RH
    Store temperature and humidity -20¡æ~+85¡æ,10%~95%%RH
    Overall dimension 150*140*86mm
    Weight 1.43Kgs
    Safety standard Meet UL1012
    EMC standard ......
    Note:1.The testing condition for the paramenter above is :230VAC input,rated load, 25¡æ 70% RH.Humidity
    ¡¡¡¡ 2.Error.include the setting error,line stability and load stability.(Note:5)
    ¡¡¡¡ 3.Wave test:adopting A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.
    ¡¡¡¡ 4.Inlet voltage stability test:when is over load, the lowest voltage of inlet is up to the highest voltage.
    ¡¡¡¡ 5.Load stability test:The load is from 0% to 100%
    ¡¡¡¡ 6.C3,4 must be knocked down.

    hits£º1525    addtime£º2005-10-21 £Ûback£Ý

    ¡¡
    ¡¡
    ¡¡
    ¡¡
    ¡¡

    TEL:0086-577-27838284  Fax:0086-577-56847980  E-MAIL: sales@eraelectric.com