Electrical Items >> Switching Power Supply >> S-320 Switching Power Supply ¡¡

S-320 Switching Power Supply

  • Low price and high reliability
  • 105¡æ output capacitor
  • AC input power suitable for the world
  • High efficiency and low operation temperature
  • Soft-start current can reduce the AC input impact effectiely
  • With short-circuit and owwerload protection
  • 100% full-load burning test
  • Installed with EMI filter,minimum wave
  • Model

    Performance
    S-320-5 S-320-7.5 S-320-12 S-320-13.5 S-320-15 S-320-24 S-320-27 S-320-48
    DC output voltage 5V 7.5V 12V 13.5V 15V 24V 27V 48V
    Output voltage error(Note:2) ¡À2% ¡À2% ¡À1% ¡À1% ¡À1% ¡À1% ¡À1% ¡À1%
    Rated output current 50A 36A 25A 22A 20A 12.5A 11A 6.5A
    Output current rage 0-50A 0-36A 0-25A 0-22A 0-20A 0-12.5A 0-11A 0-6.5A
    Wave and noise(Note:3) 150mVp-p 150mVp-p 180mV 180mV 180mV 180mV 240mV 240mV
    Inlet stability(Note:4) ¡À0.5% ¡À0.5% ¡À0.5% ¡À0.5% ¡À0.5% ¡À0.5% ¡À0.5% ¡À0.5%
    Load stability(Note:5) ¡À0.5% ¡À0.5% ¡À0.5% ¡À0.5% ¡À0.5% ¡À0.5% ¡À0.5% ¡À0.5%
    DC output power 250W 270W 300W 297W 300W 300W 297W 312W
    Efficiency 77% 80% 82% 83% 84% 86% 86% 87%
    Adjustable range for DC voltage 4.5-5.7V 6-9V 10-13.2V 12-15V 13.5-18V 20-26.4V 26-32V 41-56V
    Range for input votage 88~132VAC/176~264VAC SELECTED BY JUMPER OR SWTCH 47~63Hz;248~370VDC
    Input current 6A/115V 3.5A/230V
    Impact current 20A/115V 40A/230V
    Leakage current <3.5mA/240VAC
    Overload proctection

    105%~135% TYPE:PULSING HICCUP SHUTDOWN RESET£ºAUTO RECOVERY

    Over-voltage protection 5.75-6.75V 9.4-10.9V 13.8-16.2V 15.5-18.2V 18-21V 27.6-32.4V 33.7-39.2V 57.6-67.2V
    High-temperature protection RTH1>=65¡æ FAN ON<=55¡æ FAN OFF>=70¡æ Cut off output (5~15V)OUTPUT SHUTDOWN
    Temperature factor ¡À0.03%¡æ(0~50¡æ)
    Start,rise and lock time 2s,20ms,20ms
    Vibration resistance 10~500Hz,2G 10min./1cycle,time60,minutes for each shaft
    Resistance to pressure

    Input and output internal:3KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC

    Insolationg resistance Input and output internal,input and enclosure,Output and enclosure:500VAC/100M Ohms
    Operating temperature and humidity -10¡æ~+60¡æ£¬20%~90%RH
    Store temperature and humidity -20¡æ~+85¡æ,10%~95%%RH
    Overall dimension 215*115*50mm
    Weight 1.15Kgs
    Safety standard Meet UL1950
    EMC standard ¡­¡­
    Note:1.The testing condition for the paramenter above is :230VAC input,rated load, 25¡æ 70% RH.Humidity
    ¡¡¡¡ 2.Error.include the setting error,line stability and load stability.(Note:5)
    ¡¡¡¡ 3.Wave test:adopting A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.
    ¡¡¡¡ 4.Inlet voltage stability test:when is over load, the lowest voltage of inlet is up to the highest voltage.
    ¡¡¡¡ 5.Load stability test:The load is from 0% to 100%
    ¡¡¡¡ 6.C3,4,41 must be knocked down.

    hits£º1473    addtime£º2005-10-21 £Ûback£Ý

    ¡¡
    ¡¡
    ¡¡
    ¡¡
    ¡¡