¡¡ Home       About us        Products        Certificate       Feed back       Contact us
¡¡ ¡¡ ¡¡
¡¡
¡¡
Electrical Items >> Switching Power Supply >> S-100 Switching Power Supply ¡¡

S-100 Switching Power Supply(Single Way)

  • Low price and high reliability
  • 105¡æ output capacitor
  • AC input power suitable for the world
  • High efficiency and low operation temperature
  • Soft-start current can reduce the AC input impact effectiely
  • With short-circuit and owwerload protection
  • 100% full-load burning test
  • Installed with EMI filter,minimum wave
  • Model

    Performance
    S-100-3 S-100-5 S-100-7-5 S-100-12 S-100-15 S-100-24 S-100-27 S-100-48
    DC output voltage 3V 5V 7.5V 12V 15V 24V 27V 48V
    Output voltage error(Note:2) ¡À2% ¡À2% ¡À1% ¡À1% ¡À1% ¡À1% ¡À1% ¡À1%
    Rated output current 20A 20A 13.6A 8.5A 6.7A 4.5A 3.7A 2A
    Output current rage 0-20A 0-20A 0-13.6A 0-8.5A 0-6.7A 0-4.5A 0-3.7A 0-2A
    Wave and noise(Note:3) 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p
    Inlet stability(Note:4) ¡À0.5% ¡À0.5% ¡À0.5% ¡À0.3% ¡À0.3% ¡À0.2% ¡À0.2% ¡À0.2%
    Load stability(Note:5) ¡À0.5% ¡À0.5% ¡À0.5% ¡À0.3% ¡À0.3% ¡À0.2% ¡À0.2% ¡À0.2%
    DC output power 60W 100W 102W 102W 100.5W 108W 99.9W 96W
    Efficiency 70% 78% 80% 81% 81% 84% 84% 84%
    Adjustable range for DC voltage 2.85-3.3V 4.75-5.5V 6.75-8.25V 10.8-13.2V 13.5-16.5V 21.6-26.4V 26-32V 43.2-52.8V
    Range for input votage 85~132VAC,170~264VAC,47~63HZ,switch choice
    Input current 2.4A/112V 1.2A/230V
    Impact current Cool-start current30A/115V 60A/230V
    Leakage current <1mA/240VAC
    Overload proctection 105~150% 150~200% 105~150%

    TYPE RESET:RECYCLE AC ON/OFF

    Over-voltage protection ¡­¡­
    High-temperature protection ¡­¡­
    Temperature factor ¡À0.03%¡æ(0~50¡æ)
    Start,rise and lock time 200ms,80ms,20ms
    Vibration resistance 10~500Hz,2G 10min./1cycle,time60,minutes for each shaft
    Resistance to pressure

    Input and output internal:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC

    Insolationg resistance Input and output internal,input and enclosure,Output and enclosure:0500VAC/100M Ohms
    Operating temperature and humidity -10¡æ~+60¡æ£¬20%~90%RH
    Store temperature and humidity -20¡æ~+85¡æ,10%~95%RH
    Overall dimension 199*98*38mm
    Weight 0.5Kgs
    Safety standard Conform to requirement in UL1012
    EMC standard ¡­¡­
    Note:1.The testing condition for the paramenter above is :230VAC input,rated load, 25¡æ 70% RH.Humidity
    ¡¡¡¡ 2.Error.include the setting error,line stability and load stability.(Note:5)
    ¡¡¡¡ 3.Wave test:adopting A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.
    ¡¡¡¡ 4.Inlet voltage stability test:when is over load, the lowest voltage of inlet is up to the highest voltage.
    ¡¡¡¡ 5.Load stability test:The load is from 0% to 100%

    hits£º1766    addtime£º2005-10-21 £Ûback£Ý

    ¡¡
    ¡¡
    ¡¡
    ¡¡
    ¡¡

    TEL:0086-577-27838284  Fax:0086-577-56847980  E-MAIL: sales@eraelectric.com